Image processing technique was used in a lot of studies and research and it concluded , including a number of mathematical relations . In this study , two programs were used , the first one; MATLAB
program and second Image-J program . These programs were used to tracks analysis of α - particles on the nuclear track detectors type CR-39 and CN-85 . Where irradiated detectors by thermal neutrons from(241Am-9Be) source with activity 12Ci and neutron flux 105 n.cm-2.s-1 . Which obtained on incident αparticles for detectors through 10 B(n, α)7Li interaction after covered it with boric acid H pellets . The irradiation times - TD for both detectors were 4h , 8h , 16h and 24h Through the analyze irradiated detectors of using MATLAB outputs for found the following relationships: a)The irradiation time -T has behavior linear relationships with following nuclear track parameters, Total track number - N TD, Maximum track number - M RD 3 Bo 3 (with depended on track diameter - D at range of radiation response region 2.5µm - 4µm and 2.5µm - 5µm for CR-39 and CN-85 detector respectively) and Maximum track number - M D (without depending on track diameter - D ). b) The irradiation time -T D has behavior exponential relationship with maximum track number - M (withdepended on track area - AT) at range of radiation response region 7µm 2 - 24µm2 and 9µm for both CR-39 and CN-85 detector respectively. c) The irradiation time -T has behavior a logarithmic relationship with maximum track number - M A (without depending on track area - A D T While through the analyze of outputs Image-J program for irradiated detectors found the irradiation time -T has behavior linear relationships with following nuclear track detector parameters: a) Total track number - N D T b) Maximum track number - M RA (with depended on track area - A ) at range of radiation response region 12 µm 2 - 24µm2 and 5 µm2 - 27µm 2 T for both CR-39 and CN-85 detector respectively. c) Maximum track number - M A (without depending on track area - AT) This study show that MATLAB program was more analytical and accuracy from Image-J program through the logarithmic behavior for both detectors between irradiation time - T with the maximum track number - M A (without depending on track area - A T D). There is the possibility of future use image analysis of MATLAB program in the other nuclear track parameters analysis , including ; etched velocity- V , , track diameter- D t , critical angle of nuclear track - θ t , nuclear track depth - D p . The image analyze technique for nuclear track detector which obtained from this study especially with regard to track diameter - T can be take into account for classification of α-particle emitters , In addition to introduce this technique in preparation of nano-filters and nono-membrane in nanotechnology fields .
Digital Processing and Analysis for the Tracks Produced From the Irradiation with Neutrons Source 241 Am- 9 Be on Some of Solid State Nuclear Track Detectors
number:
3659
English
College:
department:
Degree:
Supervisor:
Dr. Hussain Ali Al-Jobouri (Assist. Professor)
year:
2016