number:
118
English
College:
department:
Degree:
Imprint:
Physics
Supervisor:
Dr. Hikmat A. Hamed
year:
1994
Abstract:
The design and construction of Freeman ion source which was carried out, which was used in wide fields such as ion implantation. The research was research steps: 1- first step: is the design of the ion source and manufacturing them to construct these parts 2. Second step: connecting the electrical circuit of the ion source and studying the plasma characteristics with and without magnetic field. 3- Third step: the extraction of the positive ions using a simple extraction electrode was performed. The effect of variations of the extraction voltage, are voltage and the filament current on the extraction current were studied.